Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Integrated earth fault protectionYes
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated voltage690 - 690V
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
Adjustment range undelayed short-circuit release800 - 4400A
Overload release current setting200 - 400A
Number of poles4
Complete device with protection unitYes
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-AE400-T-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Device construction

Built-in device slide-in technique (withdrawable)

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated voltage

690 .. 690V

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

Adjustment range undelayed short-circuit release

800 .. 4400A

Overload release current setting

200 .. 400A

Number of poles

4

Complete device with protection unit

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0