Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Type of control elementRocker lever
Number of poles4
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu400A
Motor drive integratedNo
Motor drive optionalYes
Type of electrical connection of main circuitScrew connection
Overload release current setting200 - 400A
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release800 - 4400A
With under voltage releaseNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release400 - 4000A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Integrated earth fault protectionYes
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Suitable for DIN rail (top hat rail) mountingNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-VE400-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

400A

Motor drive integrated

Motor drive optional

Type of electrical connection of main circuit

Screw connection

Overload release current setting

200 .. 400A

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

800 .. 4400A

With under voltage release

With switched-off indicator

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Position of connection for main current circuit

Front side

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Suitable for DIN rail (top hat rail) mounting

Related products