Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles4
Rated permanent current Iu400A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Overload release current setting200 - 400A
With switched-off indicatorNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionYes
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release800 - 4400A
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release400 - 4000A
With under voltage releaseNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-VE400-T-AVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles

4

Rated permanent current Iu

400A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Overload release current setting

200 .. 400A

With switched-off indicator

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

800 .. 4400A

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

400 .. 4000A

With under voltage release

Device construction

Built-in device slide-in technique (withdrawable)

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.