Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device plug-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated voltage690 - 690V
With switched-off indicatorNo
Overload release current setting320 - 400A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2400 - 4000A
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
Rated permanent current Iu400A
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Motor drive optionalYes
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Number of poles3
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-A400-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device plug-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated voltage

690 .. 690V

With switched-off indicator

Overload release current setting

320 .. 400A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2400 .. 4000A

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Complete device with protection unit

Position of connection for main current circuit

Front side

Rated permanent current Iu

400A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.