Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting315 - 630A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated permanent current Iu630A
Adjustment range undelayed short-circuit release1260 - 5040A
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Number of poles3
Integrated earth fault protectionYes
Type of control elementRocker lever
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Complete device with protection unitYes
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AE630-T-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

315 .. 630A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated permanent current Iu

630A

Adjustment range undelayed short-circuit release

1260 .. 5040A

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Integrated earth fault protection

Type of control element

Rocker lever

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Complete device with protection unit

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0