Technical specifications

Rated voltage1000 - 1000V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release800 - 4400A
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu400A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Overload release current setting200 - 400A
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release400 - 4000A
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Number of poles3
Type of control elementRocker lever
Degree of protection (IP)IP20
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VE400-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

1000 .. 1000V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

800 .. 4400A

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

400A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Overload release current setting

200 .. 400A

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

With integrated under voltage release

Motor drive integrated

DIN rail (top hat rail) mounting optional

Motor drive optional

Number of poles

3

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Complete device with protection unit

Related products