Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release3000 - 3000A
Adjustment range short-term delayed short-circuit release250 - 2500A
Overload release current setting125 - 250A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu250A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of poles4
Type of control elementRocker lever
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZML3-4-VE250

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release

3000 .. 3000A

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Overload release current setting

125 .. 250A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

250A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of poles

4

Type of control element

Rocker lever

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Complete device with protection unit

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.