Technical specifications

Rated permanent current Iu250A
Adjustment range short-term delayed short-circuit release250 - 2500A
Integrated earth fault protectionNo
Overload release current setting125 - 250A
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release3000 - 3000A
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
With integrated under voltage releaseNo
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive integratedNo
Position of connection for main current circuitFront side
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive optionalYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZML3-4-VE250-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Integrated earth fault protection

Overload release current setting

125 .. 250A

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

3000 .. 3000A

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

With integrated under voltage release

Type of control element

Rocker lever

Complete device with protection unit

Motor drive integrated

Position of connection for main current circuit

Front side

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive optional

Degree of protection (IP)

IP20

Related products