Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles4
Type of control elementRocker lever
Rated permanent current Iu1250A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Overload release current setting630 - 1250A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2500 - 15000A
With under voltage releaseNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZML4-4-AE1250/800

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

4

Type of control element

Rocker lever

Rated permanent current Iu

1250A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Motor drive optional

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Overload release current setting

630 .. 1250A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2500 .. 15000A

With under voltage release

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Related products