Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles4
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Overload release current setting80 - 160A
Motor drive integratedNo
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitFrame clamp
Rated voltage690 - 690V
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1920 - 1920A
Adjustment range short-term delayed short-circuit release160 - 1600A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-VE160-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

4

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

80 .. 160A

Motor drive integrated

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Frame clamp

Rated voltage

690 .. 690V

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1920 .. 1920A

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Position of connection for main current circuit

Front side

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Related products