Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated voltage690 - 690V
Rated permanent current Iu400A
Overload release current setting200 - 400A
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release800 - 4400A
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionYes
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact0
Number of poles4
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-AE400/250-T-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated voltage

690 .. 690V

Rated permanent current Iu

400A

Overload release current setting

200 .. 400A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

800 .. 4400A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as change-over contact

0

Number of poles

4

With integrated under voltage release

Complete device with protection unit

Motor drive optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive integrated

Related products