Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Position of connection for main current circuitFront side
Number of poles4
Number of auxiliary contacts as change-over contact0
Overload release current setting315 - 630A
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Rated permanent current Iu630A
Type of control elementRocker lever
Motor drive optionalYes
Motor drive integratedNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release472.5 - 4410A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device plug-in technique
Type of electrical connection of main circuitScrew connection
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Adjustment range undelayed short-circuit release1260 - 5040A
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-VE630/400-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front side

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Overload release current setting

315 .. 630A

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Rated permanent current Iu

630A

Type of control element

Rocker lever

Motor drive optional

Motor drive integrated

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

472.5 .. 4410A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device plug-in technique

Type of electrical connection of main circuit

Screw connection

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Adjustment range undelayed short-circuit release

1260 .. 5040A

With switched-off indicator

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.