Technical specifications

Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Type of control elementRocker lever
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release630 - 6300A
Integrated earth fault protectionNo
Complete device with protection unitYes
Overload release current setting315 - 630A
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
With under voltage releaseNo
Adjustment range undelayed short-circuit release1260 - 6930A
Device constructionBuilt-in device plug-in technique
Motor drive integratedNo
Rated permanent current Iu630A
Number of poles3
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VE630-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Type of control element

Rocker lever

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

630 .. 6300A

Integrated earth fault protection

Complete device with protection unit

Overload release current setting

315 .. 630A

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

With under voltage release

Adjustment range undelayed short-circuit release

1260 .. 6930A

Device construction

Built-in device plug-in technique

Motor drive integrated

Rated permanent current Iu

630A

Number of poles

3

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA