  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles3
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu630A
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Motor drive integratedNo
Overload release current setting315 - 630A
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device plug-in technique
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1260 - 6930A
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release630 - 6300A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VE630-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

630A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Motor drive integrated

Overload release current setting

315 .. 630A

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device plug-in technique

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1260 .. 6930A

With switched-off indicator

Adjustment range short-term delayed short-circuit release

630 .. 6300A

Position of connection for main current circuit

Front side

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA