Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionYes
Overload release current setting315 - 630A
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Complete device with protection unitYes
Number of poles3
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive optionalYes
Adjustment range undelayed short-circuit release1260 - 5040A
With integrated under voltage releaseNo
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release472 - 4410A
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VE630-T-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Overload release current setting

315 .. 630A

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Complete device with protection unit

Number of poles

3

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive optional

Adjustment range undelayed short-circuit release

1260 .. 5040A

With integrated under voltage release

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

472 .. 4410A

Motor drive integrated

Related products