Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as change-over contact0
Rated permanent current Iu65A
Overload release current setting30 - 65A
Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Type of control elementTurn button
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitOther
Suitable for DIN rail (top hat rail) mountingYes
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release150 - 150A
Adjustment range undelayed short-circuit release1008 - 1008A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKE65/XTUCP-65

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

65A

Overload release current setting

30 .. 65A

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Type of control element

Turn button

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Other

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

150 .. 150A

Adjustment range undelayed short-circuit release

1008 .. 1008A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.