Technical specifications

Frequency50 - 60Hz
Voltage typeAC
Built-in depth69.5mm
Rated voltage230V
Rated current25A
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
Width in number of modular spacings4
Release characteristicB
Current limiting class3
Number of poles (total)4
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Suitable for flush-mounted installationNo
Number of protected poles4
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-B25/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC

Built-in depth

69.5mm

Rated voltage

230V

Rated current

25A

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Width in number of modular spacings

4

Release characteristic

B

Current limiting class

3

Number of poles (total)

4

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Suitable for flush-mounted installation

Number of protected poles

4

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.