Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth69.5mm
Rated current1A
Frequency50 - 60Hz
Voltage typeAC
Rated voltage230V
Over voltage category3
Current limiting class3
Concurrently switching neutral conductorNo
Number of protected poles4
Rated insulation voltage Ui440V
Pollution degree2
Degree of protection (IP)IP20
Release characteristicC
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-C1/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

69.5mm

Rated current

1A

Frequency

50 .. 60Hz

Voltage type

AC

Rated voltage

230V

Over voltage category

3

Current limiting class

3

Concurrently switching neutral conductor

Number of protected poles

4

Rated insulation voltage Ui

440V

Pollution degree

2

Degree of protection (IP)

IP20

Release characteristic

C

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.