  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Width in number of modular spacings4
Release characteristicD
Voltage typeAC
Rated insulation voltage Ui440V
Rated current1.6A
Current limiting class3
Connectable conductor cross section multi-wired1 - 25mm²
Built-in depth69.5mm
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Over voltage category3
Pollution degree2
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

PL7-D1,6/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Width in number of modular spacings

4

Release characteristic

D

Voltage type

AC

Rated insulation voltage Ui

440V

Rated current

1.6A

Current limiting class

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Built-in depth

69.5mm

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Over voltage category

3

Pollution degree

2

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.