Technical specifications

Rated voltage230V
Built-in depth69.5mm
Frequency50 - 60Hz
Rated current13A
Voltage typeAC
Release characteristicD
Rated insulation voltage Ui440V
Current limiting class3
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Width in number of modular spacings4
Number of protected poles4
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Ambient temperature during operating-25 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-D13/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

230V

Built-in depth

69.5mm

Frequency

50 .. 60Hz

Rated current

13A

Voltage type

AC

Release characteristic

D

Rated insulation voltage Ui

440V

Current limiting class

3

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Number of protected poles

4

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C