Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •SWD round cable with M12 connectors on both
  • •Cables
  • •Data and communication cable
  • •Minimum order quantity: 1 pcs
  • •EATON

Technical specifications

CategoryOther
Core identificationColour
Drain wireNo
Nominal voltage U24V
Material core insulationOther
Stranding elementPairs
Screen over stranding elementFoil
UV resistantNo
Diameter conductor1.5mm
Screen over strandingNone
Suitable for underground installationNo
Characteristic impedance100Ohm
Conductor categoryClass 2 = stranded
Number of cores5
Permitted cable outer temperature during assembling/handling-40 - 80°C
Protective sheathOther
Number of stranding elements5
Armouring/reinforcementNone
Material outer sheathPolyvinyl chloride (PVC)
Permitted cable outer temperature after assembling without vibration-40 - 80°C
Conductor surfaceBare
StrandingBundle
Outer diameter approx.5.6mm
Oil resistant (according to EN 60811-404)Yes
With rodent protectionNo
NVP value66.5%
Reaction-to-fire class according to EN 13501-6None
Cable width approx.8.2mm
Cable height approx.16.3mm
Low smoke (according to IEC 61034-2)No
Radial water blocking cableYes
Longitudinal water blocking cableNo
Halogen free (according to IEC 60754-2)No
Euro class flaming droplets/particles according to EN 13501-6None
Core identification according to HD 308 S2No
Min. permitted bending radius, moving application with forced guidance46mm
Min. permitted bending radius, stationary application/permanent installation34mm
Euro class acidity according to EN 13501-6None
Specification core insulationOther
Cable geometryRound
Specification material outer sheathPolypropylene (PP)
Min. permitted bending radius, moving application/free movement46mm
AWG size20
Material reinforcementOther
Smoke development class according to EN 13501-6None
Flame retardant according to IEC 60332-1-2No
Approved type of underground installationOther
Flame retardant according to IEC 60332-3-24 (Cat C)No
Circuit integrity according to IEC 60331-23No
Flame retardant according to IEC 60332-3-25 (Cat D)No
Suitable as telephone cableNo
Suitable as signalling cableYes
Flame retardant according to IEC 60332-3-23 (Cat B)No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Certified for shipboard applicationNo
Halogen free according to IEC 60754-1No
Number of sheath layers0
Suitable as computer data cableNo
With rip cordNo
Halogen free according to IEC 60754-3No
Flame retardant according to IEC 60332-3-22 (Cat A)No
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
Suitable for use as security alarm cableNo
DuplexNo
Nominal cross section conductor0.5mm²
Cable typeOther
Colour outer sheathGreen
Conductor materialOther
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as