Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Conductor surface
Bare
Cable type
Other
Duplex
No
Diameter conductor
1.5mm
Nominal cross section conductor
0.5mm²
Conductor category
Class 2 = stranded
AWG size
20
Number of stranding elements
19
Material core insulation
Other
Stranding element
No
Conductor material
Other
Radial water blocking cable
Yes
Core identification according to HD 308 S2
No
Longitudinal water blocking cable
Yes
Screen over stranding element
None
Core identification
Colour
Stranding
Other
Armouring/reinforcement
None
Material reinforcement
Other
Screen over stranding
None
Protective sheath
Other
Specification core insulation
Other
Specification material outer sheath
Other
Colour outer sheath
Green
Cable geometry
Round
Number of sheath layers
0
Suitable for underground installation
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Number of cores
5
Reaction-to-fire class according to EN 13501-6
None
Euro class acidity according to EN 13501-6
None
Halogen free according to IEC 60754-1
No
Halogen free (according to IEC 60754-2)
No
Flame retardant according to IEC 60332-1-2
No
Euro class flaming droplets/particles according to EN 13501-6
None
Outer diameter approx.
4.55mm
Material outer sheath
Polyurethane (PUR)
Min. permitted bending radius, moving application with forced guidance
38mm
Low smoke (according to IEC 61034-2)
No
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Circuit integrity according to IEC 60331-23
No
Approved type of underground installation
Other
Halogen free according to IEC 60754-3
No
Oil resistant (according to EN 60811-404)
Yes
Min. permitted bending radius, moving application/free movement
38mm
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Smoke development class according to EN 13501-6
None
Min. permitted bending radius, stationary application/permanent installation
34mm
Permitted cable outer temperature during assembling/handling
-25 - 80°C
Category
Other
Permitted cable outer temperature after assembling without vibration
-40 - 80°C
NVP value
66.5%
Certified for shipboard application
No
UV resistant
No
Suitable as telephone cable
No
Suitable as computer data cable
No
Suitable as signalling cable
Yes
Cable width approx.
5.6mm
With rip cord
No
Drain wire
No
Cable height approx.
16.3mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
With rodent protection
No
Suitable for use as security alarm cable
No
Compatible with Grade2TV according to XP-C 90-483
No
Compatible with Grade3TV according to XP-C 90-483
No
From same serie
SWD4-M3LR5-S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Conductor surface
Bare
Cable type
Other
Duplex
Diameter conductor
1.5mm
Nominal cross section conductor
0.5mm²
Conductor category
Class 2 = stranded
AWG size
20
Number of stranding elements
19
Material core insulation
Other
Stranding element
No
Conductor material
Other
Radial water blocking cable
Core identification according to HD 308 S2
Longitudinal water blocking cable
Screen over stranding element
None
Core identification
Colour
Stranding
Other
Armouring/reinforcement
None
Material reinforcement
Other
Screen over stranding
None
Protective sheath
Other
Specification core insulation
Other
Specification material outer sheath
Other
Colour outer sheath
Green
Cable geometry
Round
Number of sheath layers
0
Suitable for underground installation
Flame retardant according to IEC 60332-3-24 (Cat C)
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Flame retardant according to IEC 60332-3-23 (Cat B)
Number of cores
5
Reaction-to-fire class according to EN 13501-6
None
Euro class acidity according to EN 13501-6
None
Halogen free according to IEC 60754-1
Halogen free (according to IEC 60754-2)
Flame retardant according to IEC 60332-1-2
Euro class flaming droplets/particles according to EN 13501-6
None
Outer diameter approx.
4.55mm
Material outer sheath
Polyurethane (PUR)
Min. permitted bending radius, moving application with forced guidance
38mm
Low smoke (according to IEC 61034-2)
Flame retardant according to IEC 60332-3-22 (Cat A)
Circuit integrity according to IEC 60331-23
Approved type of underground installation
Other
Halogen free according to IEC 60754-3
Oil resistant (according to EN 60811-404)
Min. permitted bending radius, moving application/free movement
38mm
Flame retardant according to IEC 60332-3-25 (Cat D)
Smoke development class according to EN 13501-6
None
Min. permitted bending radius, stationary application/permanent installation
34mm
Permitted cable outer temperature during assembling/handling
-25 .. 80°C
Category
Other
Permitted cable outer temperature after assembling without vibration
-40 .. 80°C
NVP value
66.5%
Certified for shipboard application
UV resistant
Suitable as telephone cable
Suitable as computer data cable
Suitable as signalling cable
Cable width approx.
5.6mm
With rip cord
Drain wire
Cable height approx.
16.3mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
With rodent protection
Suitable for use as security alarm cable
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
From same serie
We use cookies to enhance your experience.