Aleta.hr

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Material core insulationOther
Nominal cross section conductor0.5mm²
UV resistantNo
Nominal voltage U24V
Core identificationColour
Colour outer sheathGreen
Cable typeOther
Drain wireNo
Stranding elementNo
Conductor materialOther
Diameter conductor1.5mm
CategoryOther
Screen over stranding elementNone
Material outer sheathPolyurethane (PUR)
Screen over strandingNone
Conductor categoryClass 2 = stranded
Protective sheathOther
Halogen free (according to IEC 60754-2)No
Characteristic impedance100Ohm
Permitted cable outer temperature after assembling without vibration-40 - 80°C
Number of stranding elements19
Suitable for underground installationNo
Number of cores5
Permitted cable outer temperature during assembling/handling-25 - 80°C
Armouring/reinforcementNone
Cable height approx.16.3mm
Low smoke (according to IEC 61034-2)No
Cable width approx.5.6mm
Smoke development class according to EN 13501-6None
NVP value66.5%
Oil resistant (according to EN 60811-404)Yes
Conductor surfaceBare
With rodent protectionNo
Reaction-to-fire class according to EN 13501-6None
StrandingOther
Radial water blocking cableYes
Longitudinal water blocking cableYes
Outer diameter approx.4.55mm
Cable geometryRound
Specification material outer sheathOther
Min. permitted bending radius, stationary application/permanent installation34mm
Specification core insulationOther
Euro class flaming droplets/particles according to EN 13501-6None
Euro class acidity according to EN 13501-6None
Core identification according to HD 308 S2No
Suitable as computer data cableNo
Material reinforcementOther
Min. permitted bending radius, moving application/free movement38mm
AWG size20
Min. permitted bending radius, moving application with forced guidance38mm
Certified for shipboard applicationNo
Approved type of underground installationOther
Flame retardant according to IEC 60332-1-2No
Suitable as telephone cableNo
Suitable as signalling cableYes
Flame retardant according to IEC 60332-3-25 (Cat D)No
Flame retardant according to IEC 60332-3-24 (Cat C)No
Halogen free according to IEC 60754-1No
Flame retardant according to IEC 60332-3-23 (Cat B)No
Circuit integrity according to IEC 60331-23No
Flame retardant according to IEC 60332-3-22 (Cat A)No
Halogen free according to IEC 60754-3No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Compatible with Grade3TV according to XP-C 90-483No
DuplexNo
With rip cordNo
Suitable for use as security alarm cableNo
Compatible with Grade2TV according to XP-C 90-483No
Number of sheath layers0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-M3LR5-S

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Material core insulation

Other

Nominal cross section conductor

0.5mm²

UV resistant

Nominal voltage U

24V

Core identification

Colour

Colour outer sheath

Green

Cable type

Other

Drain wire

Stranding element

No

Conductor material

Other

Diameter conductor

1.5mm

Category

Other

Screen over stranding element

None

Material outer sheath

Polyurethane (PUR)

Screen over stranding

None

Conductor category

Class 2 = stranded

Protective sheath

Other

Halogen free (according to IEC 60754-2)

Characteristic impedance

100Ohm

Permitted cable outer temperature after assembling without vibration

-40 .. 80°C

Number of stranding elements

19

Suitable for underground installation

Number of cores

5

Permitted cable outer temperature during assembling/handling

-25 .. 80°C

Armouring/reinforcement

None

Cable height approx.

16.3mm

Low smoke (according to IEC 61034-2)

Cable width approx.

5.6mm

Smoke development class according to EN 13501-6

None

NVP value

66.5%

Oil resistant (according to EN 60811-404)

Conductor surface

Bare

With rodent protection

Reaction-to-fire class according to EN 13501-6

None

Stranding

Other

Radial water blocking cable

Longitudinal water blocking cable

Outer diameter approx.

4.55mm

Cable geometry

Round

Specification material outer sheath

Other

Min. permitted bending radius, stationary application/permanent installation

34mm

Specification core insulation

Other

Euro class flaming droplets/particles according to EN 13501-6

None

Euro class acidity according to EN 13501-6

None

Core identification according to HD 308 S2

Suitable as computer data cable

Material reinforcement

Other

Min. permitted bending radius, moving application/free movement

38mm

AWG size

20

Min. permitted bending radius, moving application with forced guidance

38mm

Certified for shipboard application

Approved type of underground installation

Other

Flame retardant according to IEC 60332-1-2

Suitable as telephone cable

Suitable as signalling cable

Flame retardant according to IEC 60332-3-25 (Cat D)

Flame retardant according to IEC 60332-3-24 (Cat C)

Halogen free according to IEC 60754-1

Flame retardant according to IEC 60332-3-23 (Cat B)

Circuit integrity according to IEC 60331-23

Flame retardant according to IEC 60332-3-22 (Cat A)

Halogen free according to IEC 60754-3

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Compatible with Grade3TV according to XP-C 90-483

Duplex

With rip cord

Suitable for use as security alarm cable

Compatible with Grade2TV according to XP-C 90-483

Number of sheath layers

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.