Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU1E-SWD-1DX

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Suitable for safety functions
Number of digital outputs
0
Width
56.9mm
Input current at signal 1
4mA
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Supporting protocol for LON
Supporting protocol for PROFIBUS
Time delay at signal exchange
0 .. 0.2ms
Height
20.1mm
Supporting protocol for TCP/IP
Depth
85.6mm
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Voltage type of supply voltage
DC
With optical interface
Number of digital inputs
1
Supporting protocol for CAN
Supporting protocol for ASI
Number of HW-interfaces RS-232
0
Type of voltage (input voltage)
DC
Type of electric connection
Screw connection
Supporting protocol for Data-Highway
Explosion safety category for dust
None
Appendant operation agent (Ex ib)
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet
Explosion safety category for gas
None
Supporting protocol for KNX
Degree of protection (IP)
IP69K
Appendant operation agent (Ex ia)
Type of digital output
None
Output current
0A
Supporting protocol for other bus systems
Fieldbus connection over separate bus coupler possible
Supporting protocol for SERCOS
Supporting protocol for SUCONET
Short-circuit protection, outputs available
Rail mounting possible
Supporting protocol for Modbus
System accessory
Supporting protocol for INTERBUS
Number of interfaces PROFINET
0
Front built-in possible
Rack-assembly possible
Number of HW-interfaces Wireless
0
IO link master
Wall mounting/direct mounting
Permitted voltage at input
20.4 .. 28.8V
Radio standard Bluetooth
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Radio standard Wi-Fi 802.11
Supply voltage DC
0 .. 28.8V
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET IO
Supply voltage AC 60 Hz
0 .. 0V
Permitted voltage at output
20.4 .. 28.8V
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Performance level according to EN ISO 13849-1
None
Supply voltage AC 50 Hz
0 .. 0V
Radio standard GPRS
SIL according to IEC 61508
None
Type of output voltage
DC
Digital inputs configurable
Radio standard GSM
Radio standard UMTS
Digital outputs configurable
Supporting protocol for EtherCAT
Certified for UL hazardous location class II
Certified for UL hazardous location division 1
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location class I
Certified for UL hazardous location division 2
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location class III