EU2E-SWD-4DD-1
Code: 1640471

EU2E-SWD-4DD-1

Supply voltage AC 60 Hz
0 .. 0V
Number of digital inputs
4
Input current at signal 1
4mA
Permitted voltage at input
20.4 .. 28.8V
Supply voltage AC 50 Hz
0 .. 0V
Number of digital outputs
4
Digital inputs configurable
Digital outputs configurable
Supply voltage DC
0 .. 28.8V
Type of voltage (input voltage)
DC
Voltage type of supply voltage
DC
Type of digital output
Other
Output current
0.5A
Type of output voltage
DC
Short-circuit protection, outputs available
Number of HW-interfaces industrial Ethernet
0
Permitted voltage at output
20.4 .. 28.8V
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
With optical interface
Number of HW-interfaces other
0
Supporting protocol for INTERBUS
Supporting protocol for EtherCAT
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Radio standard Bluetooth
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
Radio standard Wi-Fi 802.11
IO link master
System accessory
Degree of protection (IP)
IP69K
Type of electric connection
Screw connection
Time delay at signal exchange
0 .. 0.2ms
Front built-in possible
Wall mounting/direct mounting
Rack-assembly possible
Suitable for safety functions
Rail mounting possible
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Performance level according to EN ISO 13849-1
None
Fieldbus connection over separate bus coupler possible
Appendant operation agent (Ex ib)
Explosion safety category for dust
None
Explosion safety category for gas
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Height
40mm
Width
80mm
Depth
110mm
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Supporting protocol for PROFINET CBA