Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Input current at signal 14mA
Number of HW-interfaces RS-4850
Height40mm
Time delay at signal exchange0 - 0.2ms
Width80mm
Depth110mm
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Type of voltage (input voltage)DC
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Suitable for safety functionsNo
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Output current0.5A
Explosion safety category for gasNone
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleYes
Supporting protocol for ModbusNo
Explosion safety category for dustNone
System accessoryYes
Short-circuit protection, outputs availableYes
Type of digital outputOther
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Number of interfaces PROFINET0
Fieldbus connection over separate bus coupler possibleYes
Type of electric connectionScrew connection
Number of HW-interfaces Wireless0
Wall mounting/direct mountingYes
Rack-assembly possibleNo
Front built-in possibleNo
IO link masterNo
Radio standard BluetoothNo
Supporting protocol for PROFINET CBANo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supply voltage AC 60 Hz0 - 0V
Type of output voltageDC
Supply voltage DC0 - 28.8V
Supporting protocol for PROFIsafeNo
Digital inputs configurableYes
Radio standard GPRSNo
Supporting protocol for AS-Interface Safety at WorkNo
Digital outputs configurableYes
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Permitted voltage at input20.4 - 28.8V
Permitted voltage at output20.4 - 28.8V
Supply voltage AC 50 Hz0 - 0V
Radio standard GSMNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherCATNo
Radio standard UMTSNo
SIL according to IEC 61508None
Certified for UL hazardous location division 2No
Certified for UL hazardous location class INo
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Number of digital inputs4
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP69K

Related products