Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Input current at signal 14mA
Number of HW-interfaces RS-4850
Height40mm
Time delay at signal exchange0 - 0.2ms
Width80mm
Depth110mm
Supporting protocol for LONNo
Voltage type of supply voltageDC
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of digital outputs4
Type of voltage (input voltage)DC
Number of digital inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Suitable for safety functionsNo
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Output current0.5A
Explosion safety category for gasNone
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleYes
Supporting protocol for ModbusNo
Explosion safety category for dustNone
System accessoryYes
Short-circuit protection, outputs availableYes
Type of digital outputOther
Supporting protocol for SERCOSNo
Degree of protection (IP)IP69K
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Number of interfaces PROFINET0
Fieldbus connection over separate bus coupler possibleYes
Type of electric connectionScrew connection
Number of HW-interfaces Wireless0
Wall mounting/direct mountingYes
Rack-assembly possibleNo
Front built-in possibleNo
IO link masterNo
Radio standard BluetoothNo
Supporting protocol for PROFINET CBANo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supply voltage AC 60 Hz0 - 0V
Type of output voltageDC
Supply voltage DC0 - 28.8V
Supporting protocol for PROFIsafeNo
Digital inputs configurableYes
Radio standard GPRSNo
Supporting protocol for AS-Interface Safety at WorkNo
Digital outputs configurableYes
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Permitted voltage at input20.4 - 28.8V
Permitted voltage at output20.4 - 28.8V
Supply voltage AC 50 Hz0 - 0V
Radio standard GSMNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherCATNo
Radio standard UMTSNo
SIL according to IEC 61508None
Certified for UL hazardous location division 2No
Certified for UL hazardous location class INo
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EU2E-SWD-4DD-1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Input current at signal 1

4mA

Number of HW-interfaces RS-485

0

Height

40mm

Time delay at signal exchange

0 .. 0.2ms

Width

80mm

Depth

110mm

Supporting protocol for LON

Voltage type of supply voltage

DC

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of digital outputs

4

Type of voltage (input voltage)

DC

Number of digital inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Suitable for safety functions

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces other

0

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for KNX

Output current

0.5A

Explosion safety category for gas

None

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Rail mounting possible

Supporting protocol for Modbus

Explosion safety category for dust

None

System accessory

Short-circuit protection, outputs available

Type of digital output

Other

Supporting protocol for SERCOS

Degree of protection (IP)

IP69K

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Number of interfaces PROFINET

0

Fieldbus connection over separate bus coupler possible

Type of electric connection

Screw connection

Number of HW-interfaces Wireless

0

Wall mounting/direct mounting

Rack-assembly possible

Front built-in possible

IO link master

Radio standard Bluetooth

Supporting protocol for PROFINET CBA

Radio standard Wi-Fi 802.11

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supply voltage AC 60 Hz

0 .. 0V

Type of output voltage

DC

Supply voltage DC

0 .. 28.8V

Supporting protocol for PROFIsafe

Digital inputs configurable

Radio standard GPRS

Supporting protocol for AS-Interface Safety at Work

Digital outputs configurable

Supporting protocol for Foundation Fieldbus

Performance level according to EN ISO 13849-1

None

Permitted voltage at input

20.4 .. 28.8V

Permitted voltage at output

20.4 .. 28.8V

Supply voltage AC 50 Hz

0 .. 0V

Radio standard GSM

Supporting protocol for SafetyBUS p

Supporting protocol for EtherCAT

Radio standard UMTS

SIL according to IEC 61508

None

Certified for UL hazardous location division 2

Certified for UL hazardous location class I

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location class II

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location class III

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location division 1

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)