Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Diameter sensor
0mm
Height of sensor
86mm
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Length of sensor
33.5mm
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 125 V
6A
Switching function
Slow-action switch
Switching function latching
No
Number of safety auxiliary contacts
1
Output electronic
No
Number of contacts as normally closed contact
1
Type of interface
None
Forced opening
Yes
Number of contacts as normally open contact
1
Coating housing
Other
Type of interface for safety communication
None
Alignment of the control element
Roller cam straight
Material housing
Plastic
Number of contacts as change-over contact
0
Type of control element
Plunger
Type of electric connection
Connector M12
Explosion safety category for dust
None
Explosion safety category for gas
None
Degree of protection (IP)
IP66
Ambient temperature during operating
-25 - 70°C
Degree of protection (NEMA)
Other
Suitable for safety functions
Yes
With status indication
No
Construction type housing
Cuboid
From same serie
LS-11D-M12A

Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Diameter sensor
0mm
Height of sensor
86mm
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Length of sensor
33.5mm
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 125 V
6A
Switching function
Slow-action switch
Switching function latching
Number of safety auxiliary contacts
1
Output electronic
Number of contacts as normally closed contact
1
Type of interface
None
Forced opening
Number of contacts as normally open contact
1
Coating housing
Other
Type of interface for safety communication
None
Alignment of the control element
Roller cam straight
Material housing
Plastic
Number of contacts as change-over contact
0
Type of control element
Plunger
Type of electric connection
Connector M12
Explosion safety category for dust
None
Explosion safety category for gas
None
Degree of protection (IP)
IP66
Ambient temperature during operating
-25 .. 70°C
Degree of protection (NEMA)
Other
Suitable for safety functions
With status indication
Construction type housing
Cuboid