Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles3
Type of control elementDoor coupling rotary drive
Rated permanent current Iu63A
Number of auxiliary contacts as normally closed contact1
Number of auxiliary contacts as normally open contact1
Motor drive optionalNo
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Rated operation power at AC-3, 400 V30kW
Degree of protection (NEMA)Other
Degree of protection (IP), front sideIP65
Suitable for floor mountingYes
Suitable for intermediate mountingYes
Suitable for distribution board installationNo
Max. rated operation voltage Ue AC690V
Rated short-time withstand current lcw1.26kA
Conditioned rated short-circuit current Iq4kA
Rated operating voltage690 - 690V
Version as emergency stop installationNo
Version as reversing switchNo
Suitable for front mounting 4-holeNo
Rated permanent current at AC-21, 400 V63A
Voltage release optionalNo
Version as maintenance-/service switchYes
InterlockableYes
Number of switches1
Colour control elementBlack
Rated operation power at AC-23, 400 V30kW
Version as main switchYes
Suitable for front mounting centreNo
Version as safety switchNo
Switching power at 400 V30kW
Rated permanent current at AC-23, 400 V63A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

P3-63/M4/SVB-SW/HI11

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles

3

Type of control element

Door coupling rotary drive

Rated permanent current Iu

63A

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

1

Motor drive optional

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Rated operation power at AC-3, 400 V

30kW

Degree of protection (NEMA)

Other

Degree of protection (IP), front side

IP65

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Max. rated operation voltage Ue AC

690V

Rated short-time withstand current lcw

1.26kA

Conditioned rated short-circuit current Iq

4kA

Rated operating voltage

690 .. 690V

Version as emergency stop installation

Version as reversing switch

Suitable for front mounting 4-hole

Rated permanent current at AC-21, 400 V

63A

Voltage release optional

Version as maintenance-/service switch

Interlockable

Number of switches

1

Colour control element

Black

Rated operation power at AC-23, 400 V

30kW

Version as main switch

Suitable for front mounting centre

Version as safety switch

Switching power at 400 V

30kW

Rated permanent current at AC-23, 400 V

63A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.