Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Category type 2Yes
With remote signalling contactNo
Max. continuous voltage AC0V
Number of conductors (without earthing)0
Max. continuous voltage DC360V
Signalling at the deviceOptic
Nominal discharge surge current (8/20)15kA
Construction size1 modular spacing
Mounting methodOn basic element
Voltage protection level L-N0kV
Degree of protection (IP)IP20
Nominal voltage DC300V
Nominal voltage AC0V
Max. PV-voltage360V
Max. conductor cross section solid (solid, stranded)0mm²
Voltage protection level1.7kV
Voltage protection level N-PE0kV
Integrated backup fuseNo
System configuration TN-SNo
System configuration DCNo
System configuration otherNo
Leakage-current freeNo
Integrated short-circuit protectionNo
Max. overcurrent protection device, parallel connection (fuse)0A
System configuration TTNo
System configuration TN-CNo
System configuration ITYes
Max. overcurrent protection device, series connection (fuse)0A
System configuration TN-C-SNo
Max. conductor cross section flexible (fine-strand)0mm²
System configuration TNNo
Integrated short-circuit protection selective to fuse gG0A
Max. discharge surge current (8/20)0kA
Short-circuit breaking capacity (Isccr)0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPPVT12-06

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Category type 2

With remote signalling contact

Max. continuous voltage AC

0V

Number of conductors (without earthing)

0

Max. continuous voltage DC

360V

Signalling at the device

Optic

Nominal discharge surge current (8/20)

15kA

Construction size

1 modular spacing

Mounting method

On basic element

Voltage protection level L-N

0kV

Degree of protection (IP)

IP20

Nominal voltage DC

300V

Nominal voltage AC

0V

Max. PV-voltage

360V

Max. conductor cross section solid (solid, stranded)

0mm²

Voltage protection level

1.7kV

Voltage protection level N-PE

0kV

Integrated backup fuse

System configuration TN-S

System configuration DC

System configuration other

Leakage-current free

Integrated short-circuit protection

Max. overcurrent protection device, parallel connection (fuse)

0A

System configuration TT

System configuration TN-C

System configuration IT

Max. overcurrent protection device, series connection (fuse)

0A

System configuration TN-C-S

Max. conductor cross section flexible (fine-strand)

0mm²

System configuration TN

Integrated short-circuit protection selective to fuse gG

0A

Max. discharge surge current (8/20)

0kA

Short-circuit breaking capacity (Isccr)

0kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.