Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Number of conductors (without earthing)2
With remote signalling contactYes
Construction size3 modular spacing
Voltage protection level2.6kV
Max. continuous voltage AC0V
Mounting methodDIN rail (top hat rail) 35 mm
Category type 2Yes
Voltage protection level L-N0kV
Nominal voltage DC600V
Signalling at the deviceOptic
System configuration DCNo
Max. PV-voltage720V
System configuration ITYes
Max. continuous voltage DC720V
System configuration TN-CNo
System configuration TN-SNo
System configuration otherNo
System configuration TTNo
Max. conductor cross section flexible (fine-strand)0mm²
Max. discharge surge current (8/20)40kA
System configuration TNNo
Integrated short-circuit protectionNo
System configuration TN-C-SNo
Integrated backup fuseNo
Short-circuit breaking capacity (Isccr)0kA
Max. conductor cross section solid (solid, stranded)0mm²
Max. overcurrent protection device, parallel connection (fuse)0A
Voltage protection level N-PE0kV
Max. overcurrent protection device, series connection (fuse)0A
Integrated short-circuit protection selective to fuse gG0A
Leakage-current freeNo
Nominal discharge surge current (8/20)15kA
Nominal voltage AC0V
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPPVT12-06-2+PE-AX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Number of conductors (without earthing)

2

With remote signalling contact

Construction size

3 modular spacing

Voltage protection level

2.6kV

Max. continuous voltage AC

0V

Mounting method

DIN rail (top hat rail) 35 mm

Category type 2

Voltage protection level L-N

0kV

Nominal voltage DC

600V

Signalling at the device

Optic

System configuration DC

Max. PV-voltage

720V

System configuration IT

Max. continuous voltage DC

720V

System configuration TN-C

System configuration TN-S

System configuration other

System configuration TT

Max. conductor cross section flexible (fine-strand)

0mm²

Max. discharge surge current (8/20)

40kA

System configuration TN

Integrated short-circuit protection

System configuration TN-C-S

Integrated backup fuse

Short-circuit breaking capacity (Isccr)

0kA

Max. conductor cross section solid (solid, stranded)

0mm²

Max. overcurrent protection device, parallel connection (fuse)

0A

Voltage protection level N-PE

0kV

Max. overcurrent protection device, series connection (fuse)

0A

Integrated short-circuit protection selective to fuse gG

0A

Leakage-current free

Nominal discharge surge current (8/20)

15kA

Nominal voltage AC

0V

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.