  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DCNo
System configuration ITNo
System configuration TN-C-SNo
System configuration TN-SNo
System configuration TTNo
System configuration otherNo
Max. continuous voltage DC-V
Nominal voltage DC-V
Max. PV-voltage-V
Voltage protection level L-PE-kV
Voltage protection level N-PE-kV
Voltage protection level (DC+ - DC-)-kV
Voltage protection level (DC+/DC- - PE)-kV
Follow current extinguishing capability-kA
Specific energy (W/R)-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)-A
Max. overcurrent protection device, parallel connection (fuse)-A
Max. conductor cross section flexible (fine-strand)35mm²
Remote signallingNo
Energy-coordinated protection effect with regard to the terminal equipmentNo
Overcurrent protected voltage tappingNo
Voltage switching spark gap technologyNo
System configuration TNYes
System configuration TN-CYes
Nominal voltage AC230V
Lightning impulse current (10/350 µs)12.5kA
Voltage protection level1.3kV
Number of poles3
Mounting methodDIN rail (top hat rail) 35 mm
Max. conductor cross section solid (solid, stranded)35mm²
Construction size3 modular spacing
Voltage protection level L-N1.3kV
Signalling at the deviceOptic
Max. continuous voltage AC280V
Integrated backup fuseNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5093516 | V50-3+FS-280

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN-C-S

System configuration TN-S

System configuration TT

System configuration other

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

Voltage protection level L-PE

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

Max. overcurrent protection device, series connection (fuse)

-A

Max. overcurrent protection device, parallel connection (fuse)

-A

Max. conductor cross section flexible (fine-strand)

35mm²

Remote signalling

Energy-coordinated protection effect with regard to the terminal equipment

Overcurrent protected voltage tapping

Voltage switching spark gap technology

System configuration TN

System configuration TN-C

Nominal voltage AC

230V

Lightning impulse current (10/350 µs)

12.5kA

Voltage protection level

1.3kV

Number of poles

3

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section solid (solid, stranded)

35mm²

Construction size

3 modular spacing

Voltage protection level L-N

1.3kV

Signalling at the device

Optic

Max. continuous voltage AC

280V

Integrated backup fuse

Degree of protection (IP)

IP20