Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration ITNo
System configuration DCNo
System configuration otherNo
Number of conductors (without earthing)-
Nominal voltage DC-V
Max. continuous voltage DC-V
Max. PV-voltage-V
Voltage protection level N-PE-kV
Max. overcurrent protection device, parallel connection (fuse)-A
Max. overcurrent protection device, series connection (fuse)-A
Short-circuit breaking capacity (Isccr)-kA
Integrated short-circuit protection selective to fuse gG-A
Integrated short-circuit protectionNo
Leakage-current freeNo
Max. conductor cross section flexible (fine-strand)35mm²
With remote signalling contactNo
System configuration TNYes
System configuration TN-CYes
System configuration TN-C-SYes
System configuration TN-SYes
System configuration TTYes
Nominal discharge surge current (8/20)20kA
Max. discharge surge current (8/20)40kA
Voltage protection level L-N1.3kV
Integrated backup fuseNo
Max. continuous voltage AC280V
Construction size1 modular spacing
Voltage protection level1.3kV
Nominal voltage AC230V
Mounting methodDIN rail (top hat rail) 35 mm
Category type 2Yes
Signalling at the deviceOptic
Degree of protection (IP)IP20
Max. conductor cross section solid (solid, stranded)35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5095161 | V20-1-280

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration IT

System configuration DC

System configuration other

Number of conductors (without earthing)

-

Nominal voltage DC

-V

Max. continuous voltage DC

-V

Max. PV-voltage

-V

Voltage protection level N-PE

-kV

Max. overcurrent protection device, parallel connection (fuse)

-A

Max. overcurrent protection device, series connection (fuse)

-A

Short-circuit breaking capacity (Isccr)

-kA

Integrated short-circuit protection selective to fuse gG

-A

Integrated short-circuit protection

Leakage-current free

Max. conductor cross section flexible (fine-strand)

35mm²

With remote signalling contact

System configuration TN

System configuration TN-C

System configuration TN-C-S

System configuration TN-S

System configuration TT

Nominal discharge surge current (8/20)

20kA

Max. discharge surge current (8/20)

40kA

Voltage protection level L-N

1.3kV

Integrated backup fuse

Max. continuous voltage AC

280V

Construction size

1 modular spacing

Voltage protection level

1.3kV

Nominal voltage AC

230V

Mounting method

DIN rail (top hat rail) 35 mm

Category type 2

Signalling at the device

Optic

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.