  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Construction size3 modular spacing
Number of conductors (without earthing)-
Mounting methodDIN rail (top hat rail) 35 mm
With remote signalling contactNo
Voltage protection level1.3kV
System configuration ITNo
Category type 2Yes
Max. discharge surge current (8/20)40kA
Degree of protection (IP)IP20
Nominal discharge surge current (8/20)20kA
Max. continuous voltage DC-V
Voltage protection level L-N1.3kV
Max. overcurrent protection device, parallel connection (fuse)-A
Short-circuit breaking capacity (Isccr)-kA
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TN-C-SNo
Max. continuous voltage AC280V
Max. PV-voltage-V
System configuration DCNo
Max. conductor cross section flexible (fine-strand)35mm²
Signalling at the deviceOptic
System configuration otherNo
System configuration TTNo
Voltage protection level N-PE-kV
System configuration TNYes
System configuration TN-CYes
System configuration TN-SNo
Integrated backup fuseNo
Nominal voltage DC-V
Nominal voltage AC230V
Max. overcurrent protection device, series connection (fuse)-A
Leakage-current freeNo
Integrated short-circuit protectionNo
Integrated short-circuit protection selective to fuse gG-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5095163 | V20-3-280

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Construction size

3 modular spacing

Number of conductors (without earthing)

-

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Voltage protection level

1.3kV

System configuration IT

Category type 2

Max. discharge surge current (8/20)

40kA

Degree of protection (IP)

IP20

Nominal discharge surge current (8/20)

20kA

Max. continuous voltage DC

-V

Voltage protection level L-N

1.3kV

Max. overcurrent protection device, parallel connection (fuse)

-A

Short-circuit breaking capacity (Isccr)

-kA

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-C-S

Max. continuous voltage AC

280V

Max. PV-voltage

-V

System configuration DC

Max. conductor cross section flexible (fine-strand)

35mm²

Signalling at the device

Optic

System configuration other

System configuration TT

Voltage protection level N-PE

-kV

System configuration TN

System configuration TN-C

System configuration TN-S

Integrated backup fuse

Nominal voltage DC

-V

Nominal voltage AC

230V

Max. overcurrent protection device, series connection (fuse)

-A

Leakage-current free

Integrated short-circuit protection

Integrated short-circuit protection selective to fuse gG

-A