Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Nominal voltage DC-V
Number of conductors (without earthing)-
Voltage protection level L-N2kV
Max. continuous voltage AC440V
Signalling at the deviceOptic
Construction size1 modular spacing
Category type 2Yes
Nominal voltage AC400V
Nominal discharge surge current (8/20)20kA
Mounting methodDIN rail (top hat rail) 35 mm
With remote signalling contactNo
Voltage protection level2kV
System configuration otherNo
System configuration TN-SYes
System configuration TNYes
System configuration TN-C-SYes
System configuration TTYes
System configuration TN-CYes
Max. conductor cross section flexible (fine-strand)35mm²
Max. overcurrent protection device, series connection (fuse)-A
Integrated short-circuit protection selective to fuse gG-A
Max. continuous voltage DC585V
Max. PV-voltage-V
Leakage-current freeNo
Max. discharge surge current (8/20)40kA
Max. overcurrent protection device, parallel connection (fuse)-A
System configuration DCNo
Integrated short-circuit protectionNo
System configuration ITNo
Voltage protection level N-PE-kV
Degree of protection (IP)IP20
Max. conductor cross section solid (solid, stranded)35mm²
Integrated backup fuseNo
Short-circuit breaking capacity (Isccr)-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5095201 | V20-1-440

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Nominal voltage DC

-V

Number of conductors (without earthing)

-

Voltage protection level L-N

2kV

Max. continuous voltage AC

440V

Signalling at the device

Optic

Construction size

1 modular spacing

Category type 2

Nominal voltage AC

400V

Nominal discharge surge current (8/20)

20kA

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Voltage protection level

2kV

System configuration other

System configuration TN-S

System configuration TN

System configuration TN-C-S

System configuration TT

System configuration TN-C

Max. conductor cross section flexible (fine-strand)

35mm²

Max. overcurrent protection device, series connection (fuse)

-A

Integrated short-circuit protection selective to fuse gG

-A

Max. continuous voltage DC

585V

Max. PV-voltage

-V

Leakage-current free

Max. discharge surge current (8/20)

40kA

Max. overcurrent protection device, parallel connection (fuse)

-A

System configuration DC

Integrated short-circuit protection

System configuration IT

Voltage protection level N-PE

-kV

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

35mm²

Integrated backup fuse

Short-circuit breaking capacity (Isccr)

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.