Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- OBO
Technical specifications
Nominal voltage DC
-V
Max. conductor cross section solid (solid, stranded)
-mm²
Max. PV-voltage
-V
Voltage protection level N-PE
-kV
Max. conductor cross section flexible (fine-strand)
-mm²
With remote signalling contact
No
Max. continuous voltage DC
200V
Nominal voltage AC
120V
Nominal discharge surge current (8/20)
20kA
Voltage protection level L-N
0.8kV
Voltage protection level
0.8kV
Mounting method
On basic element
Construction size
1 modular spacing
Integrated backup fuse
No
Signalling at the device
Optic
Category type 2
Yes
Max. continuous voltage AC
150V
Degree of protection (IP)
IP20
Max. discharge surge current (8/20)
40kA
System configuration DC
No
System configuration TN-C-S
Yes
System configuration TT
Yes
System configuration TN-S
Yes
System configuration other
No
System configuration TN
Yes
System configuration TN-C
Yes
System configuration IT
No
Short-circuit breaking capacity (Isccr)
-kA
Number of conductors (without earthing)
-
From same serie
5095362 | V20-0-150

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- OBO
Technical specifications
Nominal voltage DC
-V
Max. conductor cross section solid (solid, stranded)
-mm²
Max. PV-voltage
-V
Voltage protection level N-PE
-kV
Max. conductor cross section flexible (fine-strand)
-mm²
With remote signalling contact
Max. continuous voltage DC
200V
Nominal voltage AC
120V
Nominal discharge surge current (8/20)
20kA
Voltage protection level L-N
0.8kV
Voltage protection level
0.8kV
Mounting method
On basic element
Construction size
1 modular spacing
Integrated backup fuse
Signalling at the device
Optic
Category type 2
Max. continuous voltage AC
150V
Degree of protection (IP)
IP20
Max. discharge surge current (8/20)
40kA
System configuration DC
System configuration TN-C-S
System configuration TT
System configuration TN-S
System configuration other
System configuration TN
System configuration TN-C
System configuration IT
Short-circuit breaking capacity (Isccr)
-kA
Number of conductors (without earthing)
-
From same serie