Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
With switched-off indicatorNo
Type of control elementToggle
Adjustment range undelayed short-circuit release450 - 450A
Motor drive optionalYes
Overload release current setting14.0 - 20A
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Position of connection for main current circuitFront side
Number of poles3
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA080826R1 | XT1C 160 TMD 20-450 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

With switched-off indicator

Type of control element

Toggle

Adjustment range undelayed short-circuit release

450 .. 450A

Motor drive optional

Overload release current setting

14.0 .. 20A

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Position of connection for main current circuit

Front side

Number of poles

3

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.