Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated voltage220 - 690V
Degree of protection (IP)IP20
Motor drive integratedNo
Overload release current setting22.4 - 32A
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Number of poles3
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release450 - 450A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA080833R1 | XT1S 160 TMD 32-450 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Motor drive integrated

Overload release current setting

22.4 .. 32A

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Integrated earth fault protection

Adjustment range undelayed short-circuit release

450 .. 450A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.