Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu160A
Adjustment range undelayed short-circuit release450 - 450A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Overload release current setting17.5 - 25A
Rated voltage220 - 690V
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Number of poles3
With switched-off indicatorNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA080837R1 | XT1H 160 TMD 25-450 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

160A

Adjustment range undelayed short-circuit release

450 .. 450A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Overload release current setting

17.5 .. 25A

Rated voltage

220 .. 690V

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

With switched-off indicator

With integrated under voltage release

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.