Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Release characteristicB
Built-in depth69mm
Frequency50 - 60Hz
Rated current80A
Rated insulation voltage Ui440V
Rated voltage400V
Current limiting class3
Number of protected poles4
Degree of protection (IP)IP20
Pollution degree3
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 55°C
Over voltage category3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0805 | S204-B80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Release characteristic

B

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated current

80A

Rated insulation voltage Ui

440V

Rated voltage

400V

Current limiting class

3

Number of protected poles

4

Degree of protection (IP)

IP20

Pollution degree

3

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.