  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Construction size3 modular spacing
With remote signalling contactNo
Number of conductors (without earthing)3
Max. continuous voltage AC275V
Voltage protection level L-N1.25kV
Signalling at the deviceOptic
Max. continuous voltage DC-V
Nominal voltage DC-V
Integrated backup fuseNo
Nominal discharge surge current (8/20)20kA
Voltage protection level N-PE1.25kV
Degree of protection (IP)IP20
Voltage protection level1.25kV
Max. PV-voltage-V
Nominal voltage AC230V
Category type 2Yes
System configuration TN-SNo
Max. conductor cross section flexible (fine-strand)16mm²
Max. conductor cross section solid (solid, stranded)25mm²
System configuration ITNo
System configuration TN-CYes
System configuration TTNo
System configuration DCNo
System configuration TNYes
Max. discharge surge current (8/20)120kA
System configuration TN-C-SNo
Integrated short-circuit protection selective to fuse gG-A
Max. overcurrent protection device, parallel connection (fuse)125A
System configuration otherNo
Short-circuit breaking capacity (Isccr)100kA
Leakage-current freeNo
Max. overcurrent protection device, series connection (fuse)125A
Integrated short-circuit protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB803873R2400 | OVR T2 3L 40-275 P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

3 modular spacing

With remote signalling contact

Number of conductors (without earthing)

3

Max. continuous voltage AC

275V

Voltage protection level L-N

1.25kV

Signalling at the device

Optic

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Integrated backup fuse

Nominal discharge surge current (8/20)

20kA

Voltage protection level N-PE

1.25kV

Degree of protection (IP)

IP20

Voltage protection level

1.25kV

Max. PV-voltage

-V

Nominal voltage AC

230V

Category type 2

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

16mm²

Max. conductor cross section solid (solid, stranded)

25mm²

System configuration IT

System configuration TN-C

System configuration TT

System configuration DC

System configuration TN

Max. discharge surge current (8/20)

120kA

System configuration TN-C-S

Integrated short-circuit protection selective to fuse gG

-A

Max. overcurrent protection device, parallel connection (fuse)

125A

System configuration other

Short-circuit breaking capacity (Isccr)

100kA

Leakage-current free

Max. overcurrent protection device, series connection (fuse)

125A

Integrated short-circuit protection