Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20)20kA
Category type 2Yes
With remote signalling contactNo
Voltage protection level1.5kV
Number of conductors (without earthing)4
Nominal voltage AC230V
Max. continuous voltage AC275V
Nominal voltage DC-V
Construction size4 modular spacing
Max. continuous voltage DC-V
Voltage protection level L-N1.25kV
Degree of protection (IP)IP20
Signalling at the deviceOptic
Max. conductor cross section solid (solid, stranded)25mm²
Integrated backup fuseNo
Voltage protection level N-PE1.4kV
Max. PV-voltage-V
System configuration ITNo
System configuration DCNo
System configuration TN-SYes
System configuration otherNo
System configuration TN-CNo
System configuration TTYes
System configuration TNYes
Max. conductor cross section flexible (fine-strand)16mm²
System configuration TN-C-SYes
Short-circuit breaking capacity (Isccr)100kA
Max. discharge surge current (8/20)160kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB803973R1100 | OVR T2 3N 40-275 P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Nominal discharge surge current (8/20)

20kA

Category type 2

With remote signalling contact

Voltage protection level

1.5kV

Number of conductors (without earthing)

4

Nominal voltage AC

230V

Max. continuous voltage AC

275V

Nominal voltage DC

-V

Construction size

4 modular spacing

Max. continuous voltage DC

-V

Voltage protection level L-N

1.25kV

Degree of protection (IP)

IP20

Signalling at the device

Optic

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated backup fuse

Voltage protection level N-PE

1.4kV

Max. PV-voltage

-V

System configuration IT

System configuration DC

System configuration TN-S

System configuration other

System configuration TN-C

System configuration TT

System configuration TN

Max. conductor cross section flexible (fine-strand)

16mm²

System configuration TN-C-S

Short-circuit breaking capacity (Isccr)

100kA

Max. discharge surge current (8/20)

160kA