Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Mounting methodDIN rail (top hat rail) 35 mm
Construction size4 modular spacing
Max. continuous voltage AC440V
Signalling at the deviceOptic
Number of conductors (without earthing)4
Max. continuous voltage DC-V
Voltage protection level2.1kV
Nominal voltage AC230V
Voltage protection level L-N1.8kV
Max. conductor cross section flexible (fine-strand)16mm²
Max. conductor cross section solid (solid, stranded)25mm²
Integrated backup fuseNo
Nominal voltage DC-V
With remote signalling contactYes
Voltage protection level N-PE1.4kV
Nominal discharge surge current (8/20)20kA
System configuration TNYes
System configuration DCNo
System configuration ITNo
System configuration TN-CNo
System configuration TN-SYes
System configuration TTYes
System configuration otherNo
System configuration TN-C-SYes
Max. PV-voltage-V
Category type 2Yes
Max. discharge surge current (8/20)160kA
Short-circuit breaking capacity (Isccr)100kA
Max. overcurrent protection device, parallel connection (fuse)125A
Max. overcurrent protection device, series connection (fuse)125A
Integrated short-circuit protectionNo
Integrated short-circuit protection selective to fuse gG-A
Leakage-current freeYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB803973R1500 | OVR T2 3N 40-440 P TS QS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Max. continuous voltage AC

440V

Signalling at the device

Optic

Number of conductors (without earthing)

4

Max. continuous voltage DC

-V

Voltage protection level

2.1kV

Nominal voltage AC

230V

Voltage protection level L-N

1.8kV

Max. conductor cross section flexible (fine-strand)

16mm²

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated backup fuse

Nominal voltage DC

-V

With remote signalling contact

Voltage protection level N-PE

1.4kV

Nominal discharge surge current (8/20)

20kA

System configuration TN

System configuration DC

System configuration IT

System configuration TN-C

System configuration TN-S

System configuration TT

System configuration other

System configuration TN-C-S

Max. PV-voltage

-V

Category type 2

Max. discharge surge current (8/20)

160kA

Short-circuit breaking capacity (Isccr)

100kA

Max. overcurrent protection device, parallel connection (fuse)

125A

Max. overcurrent protection device, series connection (fuse)

125A

Integrated short-circuit protection

Integrated short-circuit protection selective to fuse gG

-A

Leakage-current free

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.