Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Number of conductors (without earthing)1
With remote signalling contactYes
Construction size1 modular spacing
Max. continuous voltage AC275V
Nominal discharge surge current (8/20)20kA
Voltage protection level1.4kV
Nominal voltage DC-V
Category type 2Yes
Voltage protection level N-PE1.4kV
System configuration TN-C-SYes
System configuration otherNo
System configuration TTYes
Integrated backup fuseYes
System configuration TNYes
System configuration TN-SYes
Max. PV-voltage-V
Degree of protection (IP)IP20
Short-circuit breaking capacity (Isccr)100kA
Max. conductor cross section solid (solid, stranded)35mm²
Signalling at the deviceOptic
Max. conductor cross section flexible (fine-strand)25mm²
System configuration DCNo
Max. discharge surge current (8/20)40kA
Max. continuous voltage DC-V
Nominal voltage AC230V
System configuration ITNo
System configuration TN-CNo
Voltage protection level L-N1.4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815704R0000 | OVR T2 40-275s P TS QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Number of conductors (without earthing)

1

With remote signalling contact

Construction size

1 modular spacing

Max. continuous voltage AC

275V

Nominal discharge surge current (8/20)

20kA

Voltage protection level

1.4kV

Nominal voltage DC

-V

Category type 2

Voltage protection level N-PE

1.4kV

System configuration TN-C-S

System configuration other

System configuration TT

Integrated backup fuse

System configuration TN

System configuration TN-S

Max. PV-voltage

-V

Degree of protection (IP)

IP20

Short-circuit breaking capacity (Isccr)

100kA

Max. conductor cross section solid (solid, stranded)

35mm²

Signalling at the device

Optic

Max. conductor cross section flexible (fine-strand)

25mm²

System configuration DC

Max. discharge surge current (8/20)

40kA

Max. continuous voltage DC

-V

Nominal voltage AC

230V

System configuration IT

System configuration TN-C

Voltage protection level L-N

1.4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.