Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level L-N1.4kV
Construction size4 modular spacing
Signalling at the deviceOptic
Max. continuous voltage DC-V
Max. PV-voltage-V
Nominal voltage DC-V
Integrated backup fuseYes
System configuration TNYes
System configuration DCNo
Max. conductor cross section solid (solid, stranded)35mm²
Max. conductor cross section flexible (fine-strand)25mm²
Voltage protection level N-PE1.4kV
System configuration ITNo
System configuration TN-CNo
System configuration TTNo
System configuration TN-C-SYes
System configuration TN-SYes
System configuration otherNo
Short-circuit breaking capacity (Isccr)100kA
Number of conductors (without earthing)4
Max. discharge surge current (8/20)40kA
With remote signalling contactYes
Voltage protection level1.4kV
Max. continuous voltage AC275V
Category type 2Yes
Nominal discharge surge current (8/20)20kA
Nominal voltage AC230V
Degree of protection (IP)IP20

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815704R1100 | OVR T2 4L 40-275s P TS QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level L-N

1.4kV

Construction size

4 modular spacing

Signalling at the device

Optic

Max. continuous voltage DC

-V

Max. PV-voltage

-V

Nominal voltage DC

-V

Integrated backup fuse

System configuration TN

System configuration DC

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

25mm²

Voltage protection level N-PE

1.4kV

System configuration IT

System configuration TN-C

System configuration TT

System configuration TN-C-S

System configuration TN-S

System configuration other

Short-circuit breaking capacity (Isccr)

100kA

Number of conductors (without earthing)

4

Max. discharge surge current (8/20)

40kA

With remote signalling contact

Voltage protection level

1.4kV

Max. continuous voltage AC

275V

Category type 2

Nominal discharge surge current (8/20)

20kA

Nominal voltage AC

230V

Degree of protection (IP)

IP20