Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC-V
Voltage protection level L-N-kV
Nominal voltage DC-V
Voltage protection level N-PE-kV
Max. PV-voltage-V
System configuration DCNo
System configuration ITNo
System configuration TTNo
System configuration TN-SNo
System configuration TNYes
System configuration TN-C-SNo
System configuration TN-CYes
Nominal voltage AC230V
Number of conductors (without earthing)3
Max. continuous voltage AC275V
Construction size3 modular spacing
Max. discharge surge current (8/20)120kA
Max. conductor cross section flexible (fine-strand)25mm²
Short-circuit breaking capacity (Isccr)100kA
Integrated backup fuseYes
Category type 2Yes
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level1.4kV
Max. conductor cross section solid (solid, stranded)35mm²
Degree of protection (IP)IP20
Signalling at the deviceOptic
With remote signalling contactNo
Nominal discharge surge current (8/20)20kA
System configuration otherNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815704R1800 | OVR T2 3L 40-275s P QS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Nominal voltage DC

-V

Voltage protection level N-PE

-kV

Max. PV-voltage

-V

System configuration DC

System configuration IT

System configuration TT

System configuration TN-S

System configuration TN

System configuration TN-C-S

System configuration TN-C

Nominal voltage AC

230V

Number of conductors (without earthing)

3

Max. continuous voltage AC

275V

Construction size

3 modular spacing

Max. discharge surge current (8/20)

120kA

Max. conductor cross section flexible (fine-strand)

25mm²

Short-circuit breaking capacity (Isccr)

100kA

Integrated backup fuse

Category type 2

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level

1.4kV

Max. conductor cross section solid (solid, stranded)

35mm²

Degree of protection (IP)

IP20

Signalling at the device

Optic

With remote signalling contact

Nominal discharge surge current (8/20)

20kA

System configuration other

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.