  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

With remote signalling contactYes
Mounting methodDIN rail (top hat rail) 35 mm
Construction size4 modular spacing
Nominal discharge surge current (8/20)20kA
Max. continuous voltage DC-V
Voltage protection level2kV
Max. continuous voltage AC275V
Nominal voltage DC-V
Voltage protection level N-PE2kV
Max. conductor cross section solid (solid, stranded)35mm²
Nominal voltage AC400V
Max. PV-voltage-V
Number of conductors (without earthing)4
Signalling at the deviceOptic
Integrated backup fuseYes
Degree of protection (IP)IP20
Category type 2Yes
Voltage protection level L-N1.8kV
System configuration TTYes
System configuration TN-CNo
System configuration otherNo
System configuration TN-SYes
System configuration DCNo
System configuration ITNo
System configuration TN-C-SYes
Max. conductor cross section flexible (fine-strand)25mm²
System configuration TNYes
Integrated short-circuit protectionNo
Max. overcurrent protection device, parallel connection (fuse)160A
Leakage-current freeYes
Max. overcurrent protection device, series connection (fuse)125A
Max. discharge surge current (8/20)80kA
Integrated short-circuit protection selective to fuse gG-A
Short-circuit breaking capacity (Isccr)100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815704R3700 | OVR T2 3N 40-440s P TS QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

With remote signalling contact

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Nominal discharge surge current (8/20)

20kA

Max. continuous voltage DC

-V

Voltage protection level

2kV

Max. continuous voltage AC

275V

Nominal voltage DC

-V

Voltage protection level N-PE

2kV

Max. conductor cross section solid (solid, stranded)

35mm²

Nominal voltage AC

400V

Max. PV-voltage

-V

Number of conductors (without earthing)

4

Signalling at the device

Optic

Integrated backup fuse

Degree of protection (IP)

IP20

Category type 2

Voltage protection level L-N

1.8kV

System configuration TT

System configuration TN-C

System configuration other

System configuration TN-S

System configuration DC

System configuration IT

System configuration TN-C-S

Max. conductor cross section flexible (fine-strand)

25mm²

System configuration TN

Integrated short-circuit protection

Max. overcurrent protection device, parallel connection (fuse)

160A

Leakage-current free

Max. overcurrent protection device, series connection (fuse)

125A

Max. discharge surge current (8/20)

80kA

Integrated short-circuit protection selective to fuse gG

-A

Short-circuit breaking capacity (Isccr)

100kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.