Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Number of conductors (without earthing)4
Voltage protection level3.6kV
Mounting methodDIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20)20kA
Voltage protection level L-N3.6kV
Category type 2Yes
Nominal voltage AC400V
Signalling at the deviceOptic
With remote signalling contactNo
Max. continuous voltage AC440V
Nominal voltage DC-V
Construction size4 modular spacing
Degree of protection (IP)IP20
Max. continuous voltage DC-V
Voltage protection level N-PE3.6kV
Max. PV-voltage-V
System configuration DCNo
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TN-CNo
Integrated backup fuseYes
Max. conductor cross section flexible (fine-strand)25mm²
Short-circuit breaking capacity (Isccr)100kA
Max. discharge surge current (8/20)320kA
System configuration TN-SYes
System configuration otherNo
System configuration TTNo
System configuration TNYes
System configuration ITNo
System configuration TN-C-SYes
Max. overcurrent protection device, series connection (fuse)160A
Max. overcurrent protection device, parallel connection (fuse)160A
Integrated short-circuit protection selective to fuse gG-A
Integrated short-circuit protectionNo
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815708R5200 | OVR T2 4L 80-440s P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Number of conductors (without earthing)

4

Voltage protection level

3.6kV

Mounting method

DIN rail (top hat rail) 35 mm

Nominal discharge surge current (8/20)

20kA

Voltage protection level L-N

3.6kV

Category type 2

Nominal voltage AC

400V

Signalling at the device

Optic

With remote signalling contact

Max. continuous voltage AC

440V

Nominal voltage DC

-V

Construction size

4 modular spacing

Degree of protection (IP)

IP20

Max. continuous voltage DC

-V

Voltage protection level N-PE

3.6kV

Max. PV-voltage

-V

System configuration DC

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-C

Integrated backup fuse

Max. conductor cross section flexible (fine-strand)

25mm²

Short-circuit breaking capacity (Isccr)

100kA

Max. discharge surge current (8/20)

320kA

System configuration TN-S

System configuration other

System configuration TT

System configuration TN

System configuration IT

System configuration TN-C-S

Max. overcurrent protection device, series connection (fuse)

160A

Max. overcurrent protection device, parallel connection (fuse)

160A

Integrated short-circuit protection selective to fuse gG

-A

Integrated short-circuit protection

Leakage-current free

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.