Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Construction size6 modular spacing
Number of conductors (without earthing)3
With remote signalling contactYes
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level L-N-kV
Voltage protection level N-PE-kV
Max. conductor cross section solid (solid, stranded)35mm²
Integrated backup fuseNo
Category type 2Yes
Max. continuous voltage DC-V
Signalling at the deviceOptic
Nominal voltage DC-V
Voltage protection level1.5kV
System configuration DCNo
Max. continuous voltage AC350V
Nominal voltage AC400V
Nominal discharge surge current (8/20)25kA
System configuration TNNo
System configuration TN-CYes
Max. PV-voltage-V
System configuration ITNo
Degree of protection (IP)IP20
Short-circuit breaking capacity (Isccr)25kA
System configuration otherNo
Max. discharge surge current (8/20)50kA
System configuration TTNo
System configuration TN-SNo
System configuration TN-C-SNo
Max. conductor cross section flexible (fine-strand)35mm²
Integrated short-circuit protectionNo
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

16362 | Odvodnik Pren. PRD1 Master 25 3P TIP1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Construction size

6 modular spacing

Number of conductors (without earthing)

3

With remote signalling contact

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level L-N

-kV

Voltage protection level N-PE

-kV

Max. conductor cross section solid (solid, stranded)

35mm²

Integrated backup fuse

Category type 2

Max. continuous voltage DC

-V

Signalling at the device

Optic

Nominal voltage DC

-V

Voltage protection level

1.5kV

System configuration DC

Max. continuous voltage AC

350V

Nominal voltage AC

400V

Nominal discharge surge current (8/20)

25kA

System configuration TN

System configuration TN-C

Max. PV-voltage

-V

System configuration IT

Degree of protection (IP)

IP20

Short-circuit breaking capacity (Isccr)

25kA

System configuration other

Max. discharge surge current (8/20)

50kA

System configuration TT

System configuration TN-S

System configuration TN-C-S

Max. conductor cross section flexible (fine-strand)

35mm²

Integrated short-circuit protection

Leakage-current free

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.