Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Number of poles (total)2
Rated current25A
Rated voltage400V
Number of protected poles2
Rated insulation voltage Ui690V
Release characteristicC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Over voltage category4
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Additional equipment possibleYes
Frequency50 - 60Hz
Connectable conductor cross section solid-core1.5 - 50mm²
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 35mm²
Ambient temperature during operating-30 - 70°C
Pollution degree3
Explosion-proofNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18624

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Number of poles (total)

2

Rated current

25A

Rated voltage

400V

Number of protected poles

2

Rated insulation voltage Ui

690V

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Over voltage category

4

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

1.5 .. 50mm²

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 35mm²

Ambient temperature during operating

-30 .. 70°C

Pollution degree

3

Explosion-proof

Flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.