Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicC
Built-in depth47mm
Number of protected poles2
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated insulation voltage Ui690V
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
Over voltage category4
Number of poles (total)2
Rated current63A
Concurrently switching neutral conductorYes
Frequency50 - 60Hz
Width in number of modular spacings3
Additional equipment possibleYes
Ambient temperature during operating-30 - 70°C
Pollution degree3
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section solid-core1.5 - 50mm²
Connectable conductor cross section multi-wired1 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18628

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Built-in depth

47mm

Number of protected poles

2

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated insulation voltage Ui

690V

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV

Over voltage category

4

Number of poles (total)

2

Rated current

63A

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Width in number of modular spacings

3

Additional equipment possible

Ambient temperature during operating

-30 .. 70°C

Pollution degree

3

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section solid-core

1.5 .. 50mm²

Connectable conductor cross section multi-wired

1 .. 35mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.