Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Release characteristicC
Number of poles (total)3
Rated current80A
Rated impulse withstand voltage Uimp8kV
Rated voltage400V
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Voltage typeAC/DC
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings4.5
Degree of protection (IP)IP20
Over voltage category4
Explosion-proofNo
Connectable conductor cross section multi-wired10 - 50mm²
Ambient temperature during operating-30 - 70°C
Connectable conductor cross section solid-core16 - 70mm²
Number of protected poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18640

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Release characteristic

C

Number of poles (total)

3

Rated current

80A

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Voltage type

AC/DC

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Over voltage category

4

Explosion-proof

Connectable conductor cross section multi-wired

10 .. 50mm²

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section solid-core

16 .. 70mm²

Number of protected poles

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.