Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth47mm
Voltage typeAC/DC
Frequency50 - 60Hz
Rated current80A
Pollution degree3
Current limiting class-
Rated voltage400V
Rated insulation voltage Ui690V
Number of protected poles3
Ambient temperature during operating-30 - 70°C
Number of poles (total)4
Release characteristicC
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Over voltage category4
Additional equipment possibleYes
Connectable conductor cross section solid-core16 - 70mm²
Flush-mounted installationNo
Connectable conductor cross section multi-wired10 - 50mm²
Width in number of modular spacings6
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18646 | Prekidac Mini. NG125N 25KA 3P+N 80A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

47mm

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated current

80A

Pollution degree

3

Current limiting class

-

Rated voltage

400V

Rated insulation voltage Ui

690V

Number of protected poles

3

Ambient temperature during operating

-30 .. 70°C

Number of poles (total)

4

Release characteristic

C

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Over voltage category

4

Additional equipment possible

Connectable conductor cross section solid-core

16 .. 70mm²

Flush-mounted installation

Connectable conductor cross section multi-wired

10 .. 50mm²

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.