Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 60Hz
Rated insulation voltage Ui690V
Release characteristicC
Current limiting class-
Voltage typeAC/DC
Over voltage category4
Width in number of modular spacings6
Pollution degree3
Rated voltage400V
Rated current40A
Explosion-proofNo
Connectable conductor cross section solid-core1.5 - 50mm²
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Number of protected poles4
Built-in depth47mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-30 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 35mm²
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18654

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Release characteristic

C

Current limiting class

-

Voltage type

AC/DC

Over voltage category

4

Width in number of modular spacings

6

Pollution degree

3

Rated voltage

400V

Rated current

40A

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of protected poles

4

Built-in depth

47mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-30 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.